Main Products
- Phosphonates Antiscalants, Corrosion
Inhibitors and Chelating Agents - Salts of Phosphonates
-
- Tetra Sodium Salt of 1-Hydroxy Ethylidene-1,1-Diphosphonic Acid (HEDP?Na4)
- Tetra Sodium Salt of 1-Hydroxy Ethylidene-1,1-Diphosphonic Acid (HEDP?Na4)
- 2-Phosphonobutane -1,2,4-Tricarboxylic Acid, Sodium salt (PBTC?Na4)
- Penta sodium salt of Amino Trimethylene Phosphonic Acid (ATMP?Na5)
- Hepta sodium salt of Diethylene Triamine Penta (Methylene Phosphonic Acid) (DTPMP?Na7)
- Potassium Salt of HexaMethylene-DiamineTetra (MethylenePhosphonic Acid) HMDTMPA?K6
- More
- Polycarboxylic antiscalant and dispersant
- Biodegradable antiscalant and dispersant
- Biocide and Algicide
- Built Scale & Corrosion Inhibitors and Pretreatment Filming Agents
-
- TH-907 Non-P Scale&Corrosion Inhibitor
- TH-503 Scale and Corrosion Inhibitor for Boiler
- TH-503B Scale and Corrosion Inhibitor for Boiler
- TH-504 Scale and Corrosion Inhibitor for Heating Water
- TH-601 Scale and Corrosion Inhibitor for Iron & Steel Plant
- TH-604 Scale and Corrosion Inhibitor for Power Plant
- More
- Corrosion Inhibitor
- Oxygen Scavenger
- Reverse Osmosis Chemicals
- Other
Shandong Taihe Technologies Co., Ltd.
TEL: +86-632-5113066
FAX: +86-632-5112055
E-mail: info@thwater.net
ADD: No.1, Shiliquan East Road, Shizhong District, Zaozhuang City, Shandong Province, P.R.China
TH-260 Acid Detergent for RO Membrane
Properties:
1. Suitable for all aromatic polyamide membranes.
2. Low froth formula.
3. Diluent pH 3.0-4.0.
4. Liquid chemicals, mix well.
5. Can be used repeatedly.
TH-260 is an acid liquid formula, it can remove metal hydroxide, calcium carbonate and other types of scales.
Dosage:
Dilute to 1-3%(1:45)
Specification:
Items | Index |
---|---|
Appearance | Colorless to pale yellow transparent liquid |
pH , (1% water solution) | 2.0-3.0 |
Density (20℃)g/cm3 | 1.05min |
Storage temperature | Not lower than -10℃ |
Usage:
(1)Check water box, pipeline and filter, change the filter material if needed.
(2)Input q.v. RO effluence to water box.
(3)Input q.v. TH-260 to water box, mix the solution with water pump, measure pH.
(4)Clean the system repeatedly, measure pH 5-20 minutes. After pH rise to 4, input q.v. TH-260 or acid, till pH not rise, meaning cleaning is end.
(5)If pollution is serious, sometimes the first batch detergent should be evacuated and the next batch should be required.
(6)Pay attention to solution temperature, don’t exceed the required temperature .
Package:
200L plastic drum,IBC(1000L),customers’ requirement.